Industrial automation glossary

66 terms in plain language. If a term is missing or unclear, tell us and we will add it.

#

4–20 mA loop
An analogue signalling standard where a current between 4 and 20 mA represents a measured value. 4 mA is the bottom of the range and 20 mA the top, so a reading of 0 mA signals a fault such as a broken wire.See also: Analogue input, NAMUR NE 43

A

Analogue input
A PLC input that reads a continuously varying signal, usually 0–10 V or 4–20 mA, from a sensor such as a pressure or temperature transmitter.

B

Backplane
The bus inside a rack or chassis that connects the modules to each other and to the controller, carrying power and data between them.
Braking resistor
A resistor connected to a drive that dissipates the energy a motor feeds back when it slows a high-inertia load quickly, preventing DC bus overvoltage trips.See also: DC bus, Variable frequency drive

C

Catalogue number
The manufacturer's code that identifies one specific product variant. Allen-Bradley uses this term, for example 1756-L71. Siemens calls it an order number or MLFB.See also: Order number, MLFB
Circuit breaker
A protective device that automatically interrupts current when it exceeds a set level. Miniature (MCB) and moulded-case (MCCB) breakers protect cables and equipment from overload and short circuit.
Commissioning
Testing and adjusting new or replaced equipment so it runs correctly in the plant, including checking wiring, setting parameters and proving the control sequence.
Constant torque load
A load, such as a conveyor or crusher, that needs roughly the same torque at all speeds. These need drives sized for heavy duty. Compare with variable torque loads such as fans and pumps.See also: Variable torque load
Contactor
An electrically operated switch used to start and stop motors and other heavy loads. A small control signal on the coil switches a much larger current.
Control Unit
In modular drives such as the Siemens SINAMICS G120, the part that holds the control logic, I/O and communication, separate from the Power Module that handles the motor current.
CPU
The central processing unit of a PLC. It runs the user program, reads inputs, writes outputs and handles communication.

D

DC bus
The internal DC link inside a variable frequency drive, between the rectifier and the inverter. Its voltage rises when a motor regenerates energy, which can cause an overvoltage trip.
Derating
Reducing the allowed output of a device in demanding conditions such as high temperature or altitude. Drives and power supplies are commonly derated above their rated ambient temperature and above about 1000 m altitude.
Digital input / output
A PLC channel that reads or switches a simple on/off signal, for example a limit switch input or a contactor coil output.
DIN rail
A standardised metal rail, usually 35 mm wide, on which control panel components such as terminals, relays, breakers and power supplies are clipped.
Direct on line (DOL) starter
The simplest motor starter, where the motor is connected straight to the supply through a contactor. It draws a high starting current, typically six to eight times full-load current.See also: Soft starter, Star-delta starter
Discontinued
A manufacturer status meaning a product is no longer made or sold. Spares may still exist in the market, and an upgrade path is normally published.See also: Obsolescence
Drop-in replacement
A replacement part that fits and works without any changes to wiring, mounting or the program.

E

Earth fault
An unwanted current path from a live conductor to earth. On a drive it commonly points to damaged motor cable or motor insulation.
EMC filter
A filter fitted to a drive to reduce electrical noise (electromagnetic interference) conducted back to the supply or radiated by the motor cable.
Encoder
A sensor that reports the position or speed of a shaft, used for closed-loop speed control and positioning with servos and drives.
EtherNet/IP
An industrial network protocol that carries the Common Industrial Protocol over standard Ethernet. Widely used with Allen-Bradley and Rockwell Automation systems.

F

Fault finding
Systematically diagnosing why a machine or control system is not working, to identify the actual cause rather than just replacing parts.See also: Commissioning
Fieldbus
A digital communication network connecting controllers to field devices such as drives, sensors and remote I/O. PROFIBUS and Modbus RTU are examples.
Firmware
The embedded software inside a device such as a PLC CPU or drive. Firmware version affects compatibility with engineering software and with replacement parts.
Full-load current (FLC)
The current a motor draws when delivering its rated power at rated voltage. It is printed on the nameplate and is the figure used to size drives, starters and overloads.
Function block diagram (FBD)
A graphical PLC programming language where functions are drawn as connected blocks. One of the languages defined in IEC 61131-3.See also: Ladder logic, Structured text

H

HMI
Human-machine interface. A screen or panel where operators see the state of a machine or process, change setpoints and acknowledge alarms.

I

I/O module
A PLC module that provides inputs and outputs, either digital or analogue, connecting the controller to field devices.
IE efficiency class
A classification of motor efficiency defined in IEC 60034-30-1, from IE1 (standard) up to IE4 (super premium).
Insulation resistance test
A test, often called a megger test, that measures the resistance of motor or cable insulation to earth. It should be done with the drive disconnected, because the test voltage can damage drive electronics.
IP rating
A two-digit code from IEC 60529 describing protection against solids (first digit) and water (second digit). IP65 is dust-tight and protected against water jets.See also: Ingress protection

L

Ladder logic
A graphical PLC programming language that resembles electrical relay diagrams. One of the languages defined in IEC 61131-3.See also: Function block diagram, Structured text
Last-time buy
A final opportunity to order a product before it is discontinued, usually announced by the manufacturer. Used to stock spares for the remaining life of an installation.
Lifecycle status
A manufacturer's classification of where a product is in its life, commonly active, phase-out and discontinued. Names differ between brands.
Line reactor
An inductor fitted on the supply side of a drive to reduce harmonic currents and protect the drive from supply spikes.
Load shedding
Planned interruption of electricity supply to reduce demand. For control systems, the risk is mostly at power restoration, when surges and dips can damage equipment.

M

Megger
An instrument that measures insulation resistance using a high test voltage. See insulation resistance test.
MLFB
The Siemens machine-readable product designation, better known as the order number, for example 6ES7 313-5BG04-0AB0.See also: Order number
Modbus
A simple, widely supported communication protocol. Modbus RTU runs over serial RS-485 and Modbus TCP runs over Ethernet.
Motor protection circuit breaker
A breaker designed to protect a motor and its cable against overload and short circuit, often combining the functions of a fuse and an overload relay.

N

Nameplate
The label on a motor, drive or module that lists its ratings and identification numbers. The most useful starting point when ordering a replacement.
NAMUR NE 43
A standard that defines how analogue transmitters signal faults. Currents below 3.6 mA or above 21 mA indicate a fault, and 3.8 to 20.5 mA is the valid measuring range.

O

Obsolescence
When a component can no longer be bought new from the manufacturer. Obsolescence planning means identifying these parts early and deciding between stocking spares and upgrading.
Order number
The manufacturer's code for a specific product variant. Siemens calls it the order number or MLFB. Quote the full number, including version blocks, when asking for a replacement.See also: Catalogue number, MLFB
Overload relay
A device that protects a motor from sustained overcurrent by tripping a contactor. Thermal overloads use a heating element, electronic ones measure current.

P

PID control
Proportional-integral-derivative control, a feedback method used to hold a process value such as temperature or pressure at a setpoint.
PLC
Programmable logic controller. A rugged industrial computer that reads inputs, runs a program and drives outputs to control machines and processes.
Power factor
The ratio of real power to apparent power in an AC circuit. Motors typically run at a power factor of 0.8 to 0.9 at full load.
Power Module
In modular drives, the part that contains the power electronics and connects to the motor and supply. It is paired with a Control Unit.
PROFIBUS
A long-established fieldbus standard, widely used with Siemens systems. Cabled with a dedicated shielded cable and terminated at each end.
PROFINET
An industrial Ethernet standard from the PROFIBUS organisation, used with Siemens and many other systems for real-time control and diagnostics.

R

Redundant power supply
Two power supplies connected through a redundancy module so that one can fail without interrupting the 24 V rail.
Retrofit
Upgrading part of an existing installation with newer equipment, often replacing an obsolete controller or drive while keeping the rest of the system.

S

SCADA
Supervisory control and data acquisition. Software that monitors and controls a plant or process, collecting data from many PLCs and presenting it to operators.
Service factor
A multiplier on a motor's rated power that indicates how much overload it can tolerate continuously. A service factor of 1.0 means no allowance for overload.
Servo drive
A drive that controls a servo motor with precise closed-loop control of position, speed and torque, using feedback from an encoder.
Soft starter
A device that ramps up the voltage to a motor at start, reducing starting current and mechanical shock. Unlike a drive, it does not control speed while running.See also: Direct on line starter, Variable frequency drive
Star-delta starter
A starter that connects the motor windings in star for starting and then in delta for running, reducing starting current to about a third of direct on line.
Structured text (ST)
A text-based PLC programming language, similar to Pascal. One of the languages defined in IEC 61131-3.
Surge protective device (SPD)
A device that diverts voltage surges, from lightning or switching, away from sensitive equipment. Fitted at the incoming supply and, in stages, closer to the equipment.
Synchronous speed
The speed of the rotating magnetic field in an AC motor, equal to 120 × frequency ÷ poles. At 50 Hz it is 1500 rpm for a four-pole motor.

T

TIA Portal
The Siemens engineering software used to configure and program S7-1200 and S7-1500 PLCs, HMIs and drives.

V

Variable frequency drive (VFD)
A drive that controls an AC motor's speed and torque by varying the frequency and voltage it supplies. Also called a variable speed drive or inverter.
Variable torque load
A load, such as a centrifugal fan or pump, whose torque demand falls sharply at lower speed. These can often use a drive's normal-duty rating.See also: Constant torque load

W

Watchdog
A timer in a controller that detects if the program has stopped running normally and forces a safe state or restart.